FAAC E700

PDFEmail
Automation and Control - Automation Accessories - FAAC E700
FAAC e700
Description

FAAC E700 Control Board

  • Technical Specification
  • Power supply voltage*2 230Vac (+6% -10%) - 50Hz or 115Vac (+6% -10%) - 60Hz
  • Absorbed power 20W Motor max. load 150W x 2
  • Accessories max. current (+24V) 100 mA
  • BUS Accessories max.current 400 mA
  • Operating ambient temperature -20°C - +55°C
  • Fuses*2 F1 = self-resetting; F2 = T2A-250V or T4A-120V
  • Function logics EP, A
  • Work time (time-out) 3 minute (fixed)
  • Pause time Varies according to learning (max. 10 min.)
  • Terminal board inputs Open A, Open B, Stop, BUS (I/O)
  • Connector inputs Power supply, battery module XF 433 or XF 868
  • Terminal board outputs Motors, flashing lamp, power supply to accessories, electric lock, service light contact (90 sec fixed)
  • Programmable functions Logic (A, EP), Speed (high 4.8°/sec and low 3.7°/sec)
  • Learning functions Pause time, leaf 2 delay at closing
  • Integrated radio channels type DS, SLH (max 250 channels) LC (max 250 channels - FOR SOME MARKETS ONLY)